SYSTEM Statement

Allows the states of various system parameters to be changed. An alternative to the ASSIGN statement.

Syntax

SYSTEM(parameter) = value

Syntax elements

parameter The number corresponding to the system parameter to be changed.

System parameters

Only the following system parameters can be changed:

Parameter

Function

2

Current page width (numeric).

3

Current page length (numeric).

5

Current page number (numeric).

7

Terminal type (numeric).

30

Pagination in effect (numeric).

35

Language in use (numeric).

37

Thousands separator in use (string).

38

Decimal separator in use: comma or period (string).

39

Money sign in use (string).

109

Sets the user-defined TCL logging string. If required, this can contain multiple values and subvalues.

Note

SYSTEM(109) can only set the complete TCL logging string. To change a single value or subvalue, read the current value with the SYSTEM(109) function, make your changes and then set the logging string to the new value.

Example

SYSTEM(5) = 12

Assigns the value 12 to system parameter 5, the current page number.

See also