UNIX-Connect > UNIX-Connect System Administration > The ROUTE-FILE > Connecting to a Heartbeat System

Comment on this topic

Documentation Comments

Use this form to comment on this topic. You can also provide any general observations about the Online Documentation, or request that additional information be added in a future release.

RealityV15.1Online Documentation (MoTW) Revision 7

Connecting to a Heartbeat System (UNIX-Connect Administration) (m603104+hbconnect.htm)

To

Reality

Version

Topic

Submitted by

Company

Location

Email address

Comment

 

 

Connecting to a Heartbeat System

To connect to a Heartbeat system, you will require the following ROUTE-FILE entries:

For example:

System name        : GWAY1
Entry type         : destination
Device             : /dev/rcs/tp4-fnw0
Interface type     : TLI
Provider type      : ONE
TSAP               : 0203
NSAP               : 49000108001122334401
Network info       : 
Comment            : Heartbeat Gateway 1
System name        : GWAY2
Entry type         : destination
Device             : /dev/rcs/tp4-fnw0
Interface type     : TLI
Provider type      : ONE
TSAP               : 0203
NSAP               : 49000108005566778801
Network info       : 
Comment            : Heartbeat Gateway 2
System name        : HBGWAYS
Entry type         : Alternative Host
referenced D system: GWAY1              timeout : 300
referenced D system: GWAY2              timeout : 300
Comment            : Heartbeat Gateways
System name        : OASIS
Entry type         : Q type 
Referenced D system: HBGWAYS
Referenced system  : 
Comment            : Heartbeat Database

When you connect to the Heartbeat system, you will specify the name of the Q-type entry.

RealityV15.1 (MoTW) Revision 7Comment on this topic